Sec. 23-5.15. Lean-to scaffolds
Latest version.
- (a) Limited use of lean-to scaffolds.Lean-to scaffolds shall not be used or erected to a height exceeding 10 feet above the ground, grade or equivalent surface. Lean-to scaffolds shall be used only as light duty scaffolds.(b) Scaffold construction.The spread between the legs of any lean-to scaffold, measured at the feet, shall be at least equal to one-half the height of such scaffold. The maximum span for two-inch by nine-inch planking shall be 10 feet and the maximum span for one and one-quarter inch by nine-inch planking shall be six feet. The minimum sizes of members of lean-to scaffold supports shall be as specified in Table XV of this Subpart.TABLE XV MINIMUM SPECIFICATIONS FOR LEAN–TO SCAFFOLDS