New York Codes Rules Regulations (Last Updated: March 27,2024) |
![]() |
TITLE 12. Department of Labor |
![]() |
Chapter I. Industrial Board of Appeals |
![]() |
Subchapter C. Related Regulations of the Industrial Commissioner |
![]() |
Part 80. Flammable Wearing Apparel, Fabrics, Related Materials and Interior Furnishings |
![]() |
Subpart 80-7. Rate-of-Burn Standard for Sleeping Bags |
Sec. 80-7.7. Sample preparation
Latest version.
- (a) Compression.Samples shall be compressed to ½ their original loft for 24 hours prior to testing.Note:A method of accomplishing this is to stack a number of specimens in a box and compress them all to half their original height under a board or plate held down by pins through the side of the box, etc.(a) Re-lofting.Following the 24 hour compression period, specimens shall be allowed a minimum of one hour to regain their loft before tests are conducted.