Sec. 80-7.7. Sample preparation  


Latest version.
  • (a) Compression.
    Samples shall be compressed to ½ their original loft for 24 hours prior to testing.
    Note:
    A method of accomplishing this is to stack a number of specimens in a box and compress them all to half their original height under a board or plate held down by pins through the side of the box, etc.
    (a) Re-lofting.
    Following the 24 hour compression period, specimens shall be allowed a minimum of one hour to regain their loft before tests are conducted.