Sec. 220-2.4. Source monitoring, recordkeeping, and reporting


Latest version.
  • (a) The owner or operator of a glass melting furnace located at a glass plant that meets the applicability requirements of section 220-2.1 of this Subpart must maintain a file of daily glass production rates. The production rates must be summarized monthly. Glass production records must be retained for at least five years following the date of such records and must be made available for inspection by the department during normal business hours.
    (b) The owner or operator of glass melting furnace shall demonstrate compliance with the NOx RACT emission limit(s) established in section 220-2.3(a) of this Subpart by measuring NOx emissions with a CEMS. The CEMS shall comply with the requirements of subdivision (c) of this section or with equivalent requirements approved by the department. Any approved equivalent CEMS requirements will be submitted by the department to the United States Environmental Protection Agency for approval as separate State Implementation Plan revisions.
    (c) CEMS requirements.
    (1) The owner or operator of a glass melting furnace shall install, calibrate, evaluate, operate, and maintain a CEMS, in accordance with the provisions of 40 CFR part 60, appendices A, B and F, for measuring NOx at locations approved in the CEMS certification protocol under paragraph (3) of this subdivision, and shall record the output of the system.
    (2) As part of its application for a permit or permit modification, the owner or operator of a glass melting furnace shall submit for department approval a CEMS plan.
    (3) The owner or operator of a glass melting furnace shall submit for department approval a CEMS certification protocol at least 60 days prior to CEMS certification testing. The certification protocol shall include the location of and specifications for each instrument or device, as well as procedures for calibration, operation, data evaluation, and data reporting.
    (4) The procedures in subparagraphs (i) through (v) of this paragraph shall be used for determining compliance with the NOx RACT emission limit established under section 220-2.3(a) of this Subpart.
    (i) The owner or operator of a glass melting furnace shall determine compliance daily on a 30 day rolling average basis. The 30 day rolling averages shall be calculated by dividing 30 day total NOx emissions by 30 day total glass production. Only days when the furnace operates shall be included in the 30 day rolling averages.
    (ii) At a minimum, valid CEMS data shall be obtained for 90 percent of the operating hours in each calendar quarter that the subject facility is operating.
    (iii) All valid CEMS data shall be used in calculating emission rates even if the minimum data requirements of subparagraph (ii) of this paragraph are not met.
    (iv) Along with any specific additional data requirements mandated by the department for a particular glass melting furnace, annual recertifications, quarterly accuracy, and daily calibration drift tests shall be performed in accordance with 40 CFR part 60, appendix F.
    (v) When NOx emissions data are not obtained because of CEMS downtime, or for periods when no valid CEMS data is available, emission data shall be obtained by using the 90th percentile value of all CEMS NOx emission data collected over the last 180 days.
    (5) In addition to the requirements of subparagraphs (i) through (iii) of this paragraph, the owner or operator of a glass melting furnace shall comply with the CEMS recordkeeping and reporting requirements of 40 CFR part 60, subpart A and appendix F.
    (i) The owner or operator of a glass melting furnace shall notify the department of the planned initial start-up date of any new CEMS.
    (ii) Emissions, monitoring, and operating parameter records or measurements required by this Subpart and any additional parameters required by the department shall be maintained for at least five years and made available to the department upon request.
    (iii) On a semi-annual basis, the owner or operator of a glass melting furnace shall tabulate and summarize applicable emissions, monitoring, and operating parameter measurements recorded during the preceding six months, and submit these records to the department. These records shall be submitted in a format acceptable to the department and shall include:
    (a) the 30 day rolling average NOx emissions as specified under paragraph (4) of this subdivision;
    (b) identification of the operating hours when NOx emissions data are not included in a calculation of the 30 day rolling average emissions and the reasons for not including that data;
    (c) a comparison of the NOx emissions to the NOx RACT emissions limit(s);
    (d) type and amount of fuel burned on a daily basis and the as burned heat content of the fuel;
    (e) the total daily NOx emissions and total daily glass production; and
    (f) the results of CEMS accuracy assessments as required by 40 CFR part 60, appendix F and any additional data quality information required by the department.
    (d) Protocols, reports, summaries, schedules, and any other information required to be submitted to the department under provisions of this Subpart must be sent (in either hardcopy or electronically) as follows:
    (1) one copy to the Division of Air Resources, New York State Department of Environmental Conservation, 625 Broadway, Albany, New York 12233; and
    (2) one copy to the regional air pollution control engineer at the appropriate regional office of the department.